Productinformation

BWU3857: ASi-5/ASi-3 CIP Safety™ over EtherNet/IP™ + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters

Manufacturer:
Bihl+Wiedemann

Category:
Safety Monitor / Safety PLC

Protocol:
ASi-3 ASi-5

Description:
Product description: ASi-5/ASi-3 CIP Safety over EtherNet/IP + ModbusTCP Gateway with integrated Safety Monitor, 2 ASi-5/ASi-3 masters, OPC UA server, 1 power supply for 2 ASi networks, 6 digital inputs or 3 x 2 channels safe inputs (SIL 3, cat. 4), expandable to max. 62 x 2 channels safe inputs, 1922 x 2 channels safe inputs in max. configuration, 6 release circuits (6 x fast electronic safe outputs), expandable to max. 64 safe outputs, 1984 safe outputs in max. configuration, CIP Safety via EtherNet/IP and Safe Link, diagnostic and configuration via Ethernet/IP + Modbus TCP or Ethernet diagnostic interface, duplicate address recognition, ASi fault detector, programming in C optional, IP20

Technical data
Type: Safety, EtherNet/IP + Modbus TCP, ASi-5 / ASi-3
Number of ASi networks, number of ASi Master: 2 ASi networks, 2 ASi-5/ASi-3 masters
Diagnostic and configuration interface: Ethernet fieldbus + Ethernet diagnostic
Recognition of duplicate ASi addresses: yes
ASi fault detector: yes
Protection rating: IP20
Inputs Safety, SIL 3, Cat. 4: 3 x 2 channels
Inputs digital, EDM: 6
Outputs Safety, SIL 3, cat. 4: 6 release circuits; 6 x fast electronic safe outputs
Model: Gateway with integrated Safety Monitor
Fieldbus interface: EtherNet/IP + ModbusTCP, OPC UA
1 power supply, 1 gateway for 2 ASi networks, inexpensive power supplies: yes, max. 4 A/ASi network
Programming in C: optional
Inputs safety, expandable to: max. 62 x 2 channels, max. 1922 in max. configuration
Safety outputs, independent according to SIL 3, expandable to: max. 64, max. 1984 in max. configuration
Safety communication: CIP Safety over EtherNet/IP + Safe Link

Specials:
OPC UA server
Selection of Mode of Safe Operation
Order no.
BWU3857
Product link
Open link
Datasheet